Top Guidelines Of perkinelmer autosampler

Mixing by aspiration—mixing of sample by aspiration in place of shaking ensures homogeneity in the sample and maintains cell viability

The CytKick Max Autosample includes a Increase manner that permits more rapidly sample processing, along with passive cooling for some plates/racks. A CytKick Max Accent Kit is bundled that contains 4 accessory plates: two cooling plates and two tube adaptors, in addition to a Max dongle crucial. A pc is just not integrated with the autosampler considering the fact that just one is provided with the cytometer.

To forestall probe crashes, which may have to have high-priced probe replacement, the CytKick Max Autosampler routinely performs a probe self-calibration to assist be certain steady positioning of your probe inside of each individual effectively. The self-calibration verifies good perform with the probe, reduces variability in probe positioning as time passes to forestall failures during plate runs, and will help make improvements to reliability above the life of the process.

Unlike other plate loaders that mix samples by shaking, which may not make certain homogeneity on the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing when preserving sample viability and causing consistent information with CVs under 10% throughout the plate. The CytKick Max Autosampler also has a mild mix mode for fragile cell lines.

The autosampler’s indicator lights and warning programs are already intended to ensure that a person who may have walked clear of the procedure can certainly see the technique status constantly.

To maintain system flexibility, the handbook sample probe is often available even when the loader is existing, and switching amongst tubes and plates is perkinelmer autosampler detected by way of software program and does not have to have further user intervention.

The CytKick Max Autosampler was designed to limit program down time. Automatic sampling units tend to be stricken by clogging or probe crashes. The Smart Probe, which has a 200-micron diameter that is more substantial than most probes accessible during the market, minimizes scenarios of clogging.

The intuitive application enables speedy Studying and facts analysis. One example is, a warmth map see lets rapid screening and confirmation of samples even though the instrument is attaining information.

Uncomplicated changeover—no disassembly, no additional QC, no reboot necessary for conversion involving plates and tubes

The CytKick Max Autosampler has two options for processing samples within a substantial-throughput ecosystem: higher-throughput mode and Enhance method.

Self-calibration with the probe also will allow the autosampler to become very easily moved, so it may be shared amongst many devices.

The instrument structure and software were developed with customer ease-of-use in your mind. The CytKick Max Autosampler has fluidic bottles with sensors that notify the consumer when the fluids need to get replaced.

Autocleaning of autosampler is finished in the instrument shutdown course of action thus no more consumer measures are necessary to maintain procedure.

Starting an experiment While using the Attune NxT cytometric software package is easy. Using a plate structure check out, customers can produce payment wells, outline instrument settings, and establish samples.